Fluke Portable Appliance Tester UK Kit, 6200-2-UK-Kit, 100VAC

(No reviews yet) Write a Review
Brand:
Fluke
SKU:
884822458498
Minimum Purchase:
1 unit
Item Name:
Portable Appliance Tester UK Kit
Model:
6200-2-UK-Kit
Manufacturer:
Fluke
Test Voltage:
100VAC
Brand Origin (not manufacture):
United States
Delivery Time:
2-7 Days
Unit:
Piece
See Full Product Specs
AED8,347.00

Description

Perform More Tests Each Day

The Fluke 6200-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6200-2 is designed to enable you to work faster without compromising safety – yours or your customer’s.

One-Touch Solution

Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working.

Low Weight

Weighing approximately 3 kg, the 6200-2 is lightweight and easy to carry when working on-site. The hard rugged carrying case (supplied) not only offers protection during transit but also includes extra storage space for accessories and other tools.

Small Size

This portable appliance testers is also extremely compact, and has Fluke’s traditional ruggedness to be able to withstand working in the field. Packed with all the features you need for testing portable appliances, a Fluke PAT tester is a complete all-in-one solution.

Fluke Simplifies Portable Appliance Testing
  • Dedicated key for each test for ‘one-touch’ testing
  • Pre-set pass/fail levels to save time
  • Large backlit display for easy reading
  • Single mains socket for appliance connection
  • Separate IEC socket for easy mains/extension lead testing
  • Detachable test leads for quick field replacement
  • Integral carrying handle
  • USB port for data transfer
  • Specifications
    Test specifications:
  • The accuracy specification for the display range is defined as +/-(%reading + digit counts) at 23 Deg.C +/-5 Deg.C, ?75% RH.
  • Between 0 Deg.C and 18 Deg.C and between 28 Deg.C and 40 Deg.C, accuracy specifications may degrade by 0.1 x (accuracy specification) per Deg.C.
  • The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
  • Power-on test
  • The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
  • Display range: 90 to 264V
  • Accuracy at 50Hz: +/-(2% + 3 Counts)
  • Resolution: 1V
  • Input impedance: > 1 MOhm/2.2nF
  • Maximum input mains voltage: 264V
  • Earth bond test (R pe)
  • Display Range: 0 to 19.99Ohm
  • Accuracy (after bond test zeroing): +/-(2.5% + 4 Counts)
  • Resolution: 0.01Ohm
  • Test current: 200 mA AC -0% +40% into 1.99 Ohm 25 A AC +/-20% into 25 mOhm at 230V
  • Open circuit voltage: > 4VAC, <24VAC
  • Bond test zeroing: An subtract up to 1.99 Ohm
  • Insulation test (R iso)
  • Display range: 0 to 299 MOhm
  • Accuracy: +/-(5% + 2 counts) from 0.1 to 300 MOhm\Ohm
  • Resolution: 0.01 MOhm (0 to 19.99 MOhm), 0.1 MOhm (20 to 199.9 MOhm), 1 MOhm (200 to 299 MOhm)
  • Test voltage: 500 V DC -0% + 10% at 500 kOhm load
  • Test current: > 1 mA at 500 kOhm load, < 15mA at 0 Ohm
  • Auto discharge time: < 0.5S for 1?F
  • Max. capacitive load: Operational up to 1?F
  • Touch current test
  • Display range: 0 to 1.99mA AC
  • Accuracy: +/-(4% + 2 counts)
  • Resolution: 0.01mA
  • Internal resistance (via probe): 2 kOhm
  • Measuring method: Probe
  • Substitute leakage current test
  • Display range: 0 to 19.99 mA AC
  • Accuracy: +/-(2.5% + 3 counts)
  • Resolution: 0.01mA
  • Test Voltage: 100 V AC +/-20%
  • Load/leakage test: load current
  • Display range: 0 A to 13A
  • Accuracy: +/-(4% + 2 counts)
  • Resolution: 0.1A
  • Load/leakage test: load power
  • isplay range 230 V Mains: 0.0 VA to 3.2 kVA
  • Accuracy: +/-(5% + 3 counts)
  • Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)
  • Load/leakage test: leakage current
  • Display range: 0 to 19.99 mA
  • Accuracy: +/-(4% + 4 counts)
  • Resolution: 0.01mA
  • PELV test
  • Accuracy at 50 Hz: +/-(2% + 3 counts)
  • Overload protection: 300 V rms
  • Warning threshold: 25 V rms

    • Fully downloadable PAT tester with memory and PC connectivity
    • Easy to use activate the test you need with just one button press
    • Pre-set PASS/FAIL levels, backlight, mains and IEC sockets, QWERTY keyboard and graphical display

    Items Included:
    1x Fluke 6200-2 Portable Appliance Tester, 1x Quick reference guide, 1x Hard carrying case, 1x Test lead, 1x Test probe, 1x Crocodile clip, 1x Mains cord, 1x Fluke 6200-2 Portable Appliance Tester, 1x Fail250 Appliance fail labels, 1x Pass560R Appliance pass labels, 1x EXTL100
    Item Name:
    Portable Appliance Tester UK Kit
    Model:
    6200-2-UK-Kit
    Manufacturer:
    Fluke
    Test Voltage:
    100VAC
    Brand Origin (not manufacture):
    United States
    Delivery Time:
    2-7 Days
    Unit:
    Piece
    View AllClose