Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals.
Basic specificationsMeasurement items:Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor)Measurement range:Temperature: -40.0 Deg.CC to 85.0 Deg.CC, Humidity: 0 to 100% RH at sensor environmentBasic accuracyTemperature: +/-0.5 Deg.C (main unit + sensor accuracy, at 0.0 to 35.0 Deg.C)Humidity: +/-5% rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 Deg.C / 10 to 50% RH)Storage capacityInstantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/chRecording interval1 to 30 sec., 1 to 60 min., 15 selectionsRecording modesInstantaneous recording: at every recording intervalStatistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording intervalRecording methodsOne-time recording: Stop recording when the memory capacity is fullEndless recording: Continue recording even when the memory capacity is full (old data is overwritten)Start: Logger button operation or scheduled timeStop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)Other functionsAlways backs up last recorded data; backs up recorded data and setting conditions when battery power is lowNote: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement)Power supplyLR6 (AA) Alkaline battery Ă— 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 Deg.C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 Deg.C)Accessories1x LR6 (AA) Alkaline battery (built-in internal), 1x Humidity Sensor LR9504, 1x Instruction manual, 1x Operation guide, 1x Kickstand- Easily mount the light-weight, pocket-sized loggers in tight spaces
- Easy-to-see dual display
- Transfer data to PC even during recording
- Replace batteries while recording (30 second limit) (*1)
- 7 times the memory capacity than predecessor (Record 60,000 data per channel)
- Record without missing fluctuations in STAT mode
- Measurement data is preserved even after the battery dies
- Worry-free backup preserves recorded data even if a new measurement is started by mistake